Figure 84. tdm management menu – Allied Telesis AT-S99 User Manual
Page 194

Chapter 7: Configuring the T1/E1 Ports on the AT-CM70S Media Converter Line Card
194
How to set the UART setting on the AT-CM70S Line Card is explained in
the following procedure. The procedure requires the AT-CV5M02
Management Card. The UART setting cannot be set through the Console
port on the card.
Caution
This procedure may be disruptive to network operations. The
AT-CM70S Line Card resets and initializes its management software
when the UART setting is changed. Some network traffic may be
lost.
To set the UART setting on the AT-CM70S Line Card from the menus:
1. From the Main Menu, select Module Status and Configuration. The
Module Status and Configuration Menu is shown in Figure 48 on page
128.
2. Select the AT-CM70S Line Card you want to configure. The Module
Configuration Menu is shown in Figure 53 on page 139.
3. From the Module Configuration Menu, select 3: TDM LIU (T1/E1)
Configuration to display the TDM Management Menu shown in
Figure 83.
Figure 83. TDM Management Menu
The TDM Port Configurations selection appears in the menu only
when the line card’s UART setting is set to UART backplane mode.
4. From the TDM Management Menu, select UART Configurations to
display the UART Configuration Menu, shown in Figure 84.
TDM Management Menu
Module 15, Port C
TDM Port Configurations
UART Configurations
Return to Module Configuration Menu ...