Allied Telesis AT-S99 User Manual
Page 101

AT-S73 and AT-S99 Management Software User’s Guide
101
CV1203 RPS Failure
on Remote Line Card
n
AT-CV1203
AT-CV5000
Report
The media converter line card in slot n of
the AT-CV5000 Chassis received a report
from its line card counterpart in a remote
AT-CV1203 Chassis that one of the two
power supplies connected to the remote
chassis lost power. This message
requires remote peer management. For
background information, refer to “Dying
Gasp Feature” on page 52. For
instructions on how to configure the line
cards for this feature, refer to Chapter 9,
“Configuring AT-CM Line Cards for Dying
Gasp” on page 229.
If a remote AT-CV1203 Chassis loses all
power and has at least one AT-CM Media
Converter Line Card, it sends the dying
gasp signal instead of this signal.
Clear
The media converter line card in slot n of
the AT-CV5000 Chassis received a clear
signal from its line card counterpart in a
remote AT-CV1203 Chassis, indicating
that power has been restored. This
message requires peer-to-peer
management.
Dying Gasp has
Occurred on Remote
Line Card n
AT-CV1203
AT-CV5000
Report
The media converter line card in slot n in
the AT-CV5000 Chassis received the
dying gasp signal from its line card
counterpart in a remote AT-CV1203
Chassis. The remote line card sent the
signal because the AT-CV1203 Chassis
lost power. For further information, refer to
Chapter 9, “Configuring AT-CM Line
Cards for Dying Gasp” on page 229.
Fan Tray A/B: Fan
Temperature Exceeds
Limit
AT-CV1200
AT-CV1203
AT-CV5000
Report
The temperature of the chassis exceeded
the temperature threshold.
Clear
The temperature of the chassis returned
below the temperature threshold.
Fan Tray A/B has
been Installed
AT-CV5000
Report
The AT-CVFAN Fan Module was installed
in the AT-CV5000 Chassis.
Table 9. Event Log Messages
Message
Chassis
Classi-
fication
Definition