Besides SAMPLE and SETUP, other modes the analyzer can be operated in are:

Table 6-1: Analyzer Operating modes

MODE EXPLANATION

DIAG

One of the analyzer’s diagnostic modes is active (Section 6.9).

M-P CAL

This is the basic calibration mode of the instrument and is activated by pressing
the CAL key.

SAMPLE

Sampling normally, flashing text indicates adaptive filter is on.

SAMPLE A

Indicates that unit is in SAMPLE mode and AUTOCAL feature is activated.

SETUP X.#

2

SETUP mode is being used to configure the analyzer. The gas measurement will
continue during this process.

SPAN CAL A

1

Unit is performing SPAN calibration initiated automatically by the analyzer’s

AUTOCAL feature

SPAN CAL M

1

Unit is performing SPAN calibration initiated manually by the user.

SPAN CAL R

1

Unit is performing SPAN calibration initiated remotely through the COM ports or

digital control inputs.

ZERO CAL A

1

Unit is performing ZERO calibration procedure initiated automatically by the

AUTOCAL feature

ZERO CAL M

1

Unit is performing ZERO calibration procedure initiated manually by the user.

ZERO CAL R

1

Unit is performing ZERO calibration procedure initiated remotely through the COM
ports or digital control inputs.

1

Only Appears on units with Z/S valve or IZS options

2

The revision of the analyzer firmware is displayed following the word SETUP, e.g., SETUP c.4

Finally, the various CAL modes allow calibration of the analyzer. Because of its importance, this
mode is described separately in Chapter 7.

6.2. Sample Mode

This is the analyzer’s standard operating mode. In this mode, the instrument is analyzing H

2

S

and

calculating concentrations.

6.2.1. Test Functions

A series of test functions is available at the front panel while the analyzer is in SAMPLE mode.
These parameters provide information about the present operating status of the instrument and

are useful during troubleshooting (Section 11.1.2 ). They can also be recorded in one of the iDAS
channels (Section 6.11) for data analysis. To view the test functions, press one of the

keys repeatedly in either direction.