Teledyne 6200E - Sulfides Analyzer User Manual
Page 4
Model 6200E Instruction Manual
4
M6200E Rev: A1
6.3. Calibration Mode ...................................................................................................................64
6.3.1. SETUP – PASS: Calibration Password Security .....................................................................64
6.4. Setup Mode ..........................................................................................................................66
6.4.1. SETUP Mode Password Security.........................................................................................67
6.5. SETUP – CFG: Viewing the Analyzer’s Configuration Information ..................................................67
6.6. SETUP – CLK: Setting the Internal Time-of-Day Clock.................................................................68
6.7. SETUP – RNGE: Analog Output Reporting Range Configuration .....................................................70
6.7.1. Available Analog Output Signals ........................................................................................70
6.7.2. Physical Range versus Analog Output Reporting Ranges........................................................71
6.7.3. Reporting Range Modes ...................................................................................................71
6.7.4. Single Range mode (SNGL) ..............................................................................................73
6.7.5. Independent Range Mode (IND) ........................................................................................74
6.7.6. Auto Range Mode (AUTO).................................................................................................75
6.7.7. Range Units ...................................................................................................................76
6.7.8. Dilution Ratio .................................................................................................................77
6.8. SETUP – VARS: Using the Internal Variables..............................................................................78
6.8.1. Setting the Gas Measurement Mode...................................................................................80
6.9. SETUP – DIAG: Using the Diagnostics Functions.........................................................................81
6.9.1. Accessing the Diagnostic Features .....................................................................................82
6.9.2. Signal I/O ......................................................................................................................82
6.9.3. Analog Output Step Test ..................................................................................................83
6.9.4. Analog I/O Configuration..................................................................................................84
6.9.4.1. Analog Output Signal Type and Range Span Selection ....................................................86
6.9.4.2. Analog Output Calibration Mode ..................................................................................86
6.9.4.3. Manual Analog Output Calibration and Voltage Adjustment .............................................89
6.9.4.4. Analog Output Offset Adjustment ................................................................................91
6.9.4.5. Current Loop Output Adjustment.................................................................................91
6.9.4.6. AIN Calibration.........................................................................................................93
6.9.5. Optic Test ......................................................................................................................95
6.9.6. Electrical Test .................................................................................................................96
6.9.7. Lamp Calibration.............................................................................................................97
6.9.8. Pressure Calibration ........................................................................................................98
6.9.9. Flow Calibration ..............................................................................................................99
6.9.10. Test Channel Output .................................................................................................... 100
6.10. SETUP – COMM: Setting Up the Analyser’s Communication Ports .............................................. 101
6.10.1. Analyzer ID ................................................................................................................ 101
6.10.2. COM Port Default Settings ............................................................................................ 103
6.10.3. RS-232 COM Port Cable Connections .............................................................................. 103
6.10.4. RS-485 Configuration of COM2 ...................................................................................... 104
6.10.5. DTE and DCE Communication........................................................................................ 106
6.10.6. Ethernet Card Configuration.......................................................................................... 107
6.10.6.1. Ethernet Card COM2 Communication Modes and Baud Rate......................................... 107
6.10.6.2. Configuring the Ethernet Interface Option using DHCP................................................ 107
6.10.6.3. Manually Configuring the Network IP Addresses......................................................... 110
6.10.6.4. Changing the Analyzer’s HOSTNAME ........................................................................ 112
6.10.7. Multidrop RS-232 Set Up .............................................................................................. 113
6.10.8. COM Port Communication Modes ................................................................................... 116
6.10.9. COM Port Baud Rate .................................................................................................... 118
6.10.10. COM Port Testing....................................................................................................... 119
6.11. Using the Data Acquisition System (iDAS) ............................................................................. 119
6.11.1. iDAS Structure............................................................................................................ 120
6.11.1.1. iDAS Channels...................................................................................................... 120
6.11.1.2. iDAS Parameters................................................................................................... 121
6.11.1.3. iDAS Triggering Events .......................................................................................... 122
6.11.2. Default iDAS Channels ................................................................................................. 122
6.11.2.1. Viewing iDAS Data and Settings .............................................................................. 125
6.11.2.2. Editing iDAS Data Channels .................................................................................... 126
6.11.2.3. Trigger Events ...................................................................................................... 128
6.11.2.4. Editing iDAS Parameters ........................................................................................ 128
6.11.2.5. Sample Period and Report Period............................................................................. 130
6.11.2.6. Number of Records ............................................................................................... 132
6.11.2.7. RS-232 Report Function ......................................................................................... 134