beautypg.com

Teledyne 2240 – Portable Handheld Hydrogen Leak Detector, 2nd generation User Manual

Model 2240, Portable handheld hydrogen leak detector

background image


Model 2240

IMPORTANT: SEE CRITICAL SAFETY INFORMATION

ON PAGES 1-4

Portable Handheld

Hydrogen Leak Detector

Model Number

2240

Customer Support 1-

626-934-1673

DEFAULT INSTRUMENT SETTINGS

Alarm Setting 2% Hydrogen

Analog Full Scale 2% Hydrogen

Analog Format 0-5 Volts and 4-20 mA

Manual copyright 2004

Teledyne,

Instrument software copyright 2004

Teledyne,

Wide Range Sensor® protected under US patent number 5,279,795

Page 2 of 26

M2240 R0

i. IMPORTANT NOTICES

READ THIS INSTRUCTION

MANUAL BEFORE OPERATING OR

SERVICING YOUR 2240

HYDROGEN-SPECIFIC SENSING

INSTRUMENT!!

1) HYDROGEN IS FLAMMABLE AT 4% IN

AIR.

2) BEWARE OF THE DANGER OF

APPROACHING THE FLAMMABLE
LIMIT OF HYDROGEN IN AIR! TAKE 2240
INDICATIONS SERIOUSLY AND BE
PREPARED TO TAKE ACTION TO
ELIMINATE THE DANGER. THERE IS A
HIGH PROBABILITY OF HAZARD TO
PUBLIC AND PERSONAL SAFETY!
IMMEDIATELY VACATE THE PREMISES
AND INFORM LOCAL EMERGENCY
RESPONSE PERSONNEL!

3) TO PREVENT DAMAGE TO THE 2240

SENSOR ELEMENT, NEVER
OPERATE THE UNIT IN A CONDENSING
ATMOSPHERE, TOUCH THE SENSING
ELEMENT, OR POWER DOWN 2240
BEFORE OPERATING IT IN A BENIGN