beautypg.com

Eisa configuration utility – Paradyne 6800 User Manual

Page 69

background image

COMSPHERE 6800 Series Network Management System

2-46

January 1997

6800-A2-GN22-30

EISA Configuration Utility

The EISA Configuration Utility (ECU) is a program that is shipped with the 6800 NMS
Applications software package and used to configure the System 5000 and System 15000 so that
their resources match the requirements of the circuit cards you installed. The ECU is shipped on a
floppy disk with separate disks for the System 5000 host, System 15000 host, and UIP.

To ensure that these cards function properly, you must run this program as soon as you have
finished installing the cards in either the host or the UIP.

NOTE

To run the ECU, you must connect the display unit, keyboard, and
mouse. For instructions, turn to the section entitled

System Console

in Chapter 4,

Connecting the Components.

The EISA Configuration Disk contains the ECU program and configuration files. These
configuration files describe all the circuit cards that could be installed on the Altos System 5000 or
System 15000. Table 2-8 shows the names of the configuration files depending on the type of
processor you have and the type of network connected to the processor.

Table 2-8

Configuration Files

Diskette Title

Processor

Network Type

File Name

6800 NMS ECU

System 5000 Host

Ethernet

68005E.SCI

System 5000 Host

Token Ring

68005T.SCI

6800 UIP ECU

System 5000 UIP

Ethernet

68005EU.SCI

System 5000 UIP

Token Ring

68005TU.SCI

6800 NMS ECU (15000)

System 15000

Ethernet

680015.SCI

NOTE

The configuration files supporting the Token Ring network contain

parameters for a network operating at 16 Mbps over unshielded

twisted pair (UTP) wires. If your Token Ring network has different

characteristics, you need to follow the procedures in the section

Changing the Token Ring Configuration to configure the network

properly.