To configure the IPC-1600 card, refer to Figure 2-14 and perform the following steps:
1. On the bank labeled DS1, set the memory address to E10000 with switches 1 through 8.
2. On the bank labeled DS1, set the I/O address to 110 with switches 9 through 11.
3. On the bank labeled DS2, set the IRQ to 11 with switches 1 through 8.
4. On the jumper labeled J1, check that the jumper is on Pins 2 and 3 to set the local program
memory to 16 kb.
5. Follow the instructions under Field Upgrade Procedures to install the IPC-1600 card in
Slot 8 of the UIP.
6. Once you have installed the card, you must run the EISA Configuration Utility to configure
the System 5000’s resources to match the requirements of this circuit card. For instructions,
see the section entitled EISA Configuration Utility.
7. You must reload the UIP software to specify that the IPC-1600 has been installed (see
Chapter 5, Loading and Restoring Software, for details).
491-13021-02
DS1
DS2
DS1
P3
P4
J1
Local Program
Memory Size Select
Jumper (J1)
Ribbon Cable Connections
P3 (Ports 9 – 16)
and
P4 (Ports 1 – 8)
11 10 9 8 7 6 5 4 3 2 1
ON
OFF
Push Switch to the
Indicated Position:
PIN 1
110
E10000
DS2
8 7 6 5 4 3 2 1
ON
OFF
IRQ 11
Figure 2-14. IPC-1600 — Switch and Jumper Locations and Settings