beautypg.com

Paradyne 6800 User Manual

Page 326

background image

COMSPHERE 6800 Series Network Management System

8-14

January 1997

6800-A2-GN22-30

8. Select Start Address and

PRESS: Enter

9. Select the Correct Window size/address combination and

PRESS: Enter

Addresses are listed in Table 2-1 (for 5000 host) and Table 2-5 (for 15000 host). (All
window sizes for the EMULEX DCP/MUXi cards are 16KB.) The Select Window Size
menu is displayed.

10. Select 16KB and

PRESS: Enter

11. Exit the configuration menu and return to the Main Menu:

PRESS: Esc

12. Select Run and

PRESS: Enter

NOTE

The EMULEX DCP/MUXi diagnostics automatically test to see if the
local processor can interrupt the host. The EMULEX DCP/MUXi
cards are configured without using interrupts. The diagnostics will
erroneously flag this as an error. This is not an error, so ignore the
error message.

13. The system prompts:

Local processor did not interrupt host --> FAIL

***Pausing on error ---> Type any key to continue:

PRESS: Enter

14. When the diagnostics are completed, the system prompts:

Type any key to proceed.

PRESS: Enter

The Main Menu is displayed. To test a second EMULEX DCP/MUXi card or to repeat
the test, return to Step 5. Otherwise, continue.

15. Select Exit and

PRESS: Enter

16. At the DOS prompt, remove the floppy disk and

PRESS: Ctrl + Alt + Del