beautypg.com

Paradyne 6800 User Manual

Page 148

background image

COMSPHERE 6800 Series Network Management System

4-44

January 1997

6800-A2-GN22-30

Connecting Remotely

To connect a remote NetView/PC to the host processor, you will need the following materials:

035-0153-0031 cable

002-0039-0031 connector

Two DCE devices with the following characteristics:

— Asynchronous

— Full-duplex

— Flow control ON

— Bit rates of 1200, 2400, 4800, 9600 bps

835-3564-2511 cable

To establish the connection, perform the following steps at the host processor end:

1. Connect the grounded end of a 035-0153-0031 cable to an available port on the IPC-1600

card in the host processor.

2. Connect the other end of the 035-0153-0031 cable to the 002-0039-0031 connector.

3. Connect the 002-0039-0031 connector to the local DCE device.

Perform the following steps at the remote end:

1. Connect one end of the 835-3564-2511 cable to the serial port on the NetView/PC.

2. Connect the other end of the 835-3564-2511 cable to the remote DCE devices.