Paradyne 6800 User Manual
Page 206
Loading and Restoring Software
5-45
6800-A2-GN22-30
January 1997
INIT: SINGLE USER MODE
Type CONTROL-d to proceed with normal startup,
(or give root password for system maintenance):
10. For system maintenance mode:
TYPE: root password
PRESS: Enter
NOTE
You have approximately 10 seconds to press the Enter key to select
system maintenance. Failure to do so within the 10-second window
defaults the system to normal start-up. If this occurs, a reboot is
necessary.
11. Insert the 6800 UIP Application Volume 4 floppy disk and 6800 UIP Application Volume 5
cartridge tape.
12. At the # prompt,
TYPE: installpkg
PRESS: Enter
The system prompts for the tape and floppy and prompt:
Strike enter when ready or Esc to stop
PRESS: Enter
13. After the disk and tape are read, the following message appears:
Done reading tape...
TCP/IP Runtime Serialization
Enter your serial number or enter q to quit
CAUTION
The serial number and activation key entered must be unique
across all TCP/IP nodes on the network to which the UIP is
connected. The TCP/IP daemon will shut down for both nodes
having equal serial number or activation keys.
TYPE: serial number from distribution package
PRESS: Enter
The system prompts: