Connecting the Components

4-39

6800-A2-GN22-30

January 1997

Perform the following steps at the remote end:

1. Connect one end of the 035-0151-0031 cable to the terminal port of the 839A DBU

Control Unit.

2. Connect the other end of the 035-0151-0031 cable to the DCE device.

See Appendix A, Modem Settings, for more information on optioning 3810, 3811, 3820, or
2224CEO modems for this application.

Connecting a Local Service Restoration Control Unit

To connect a local Service Restoration Control Unit (SRCU), you will need the following
materials:

035-0153-0031 cable

002-0039-0031 connector

002-0032-0031 connector

035-0152-0031 cable

To establish the connection, perform the following steps:

1. Connect the grounded end of the 035-0153-0031 cable to an available port on the IPC-1600

card in the host processor or UIP.

2. Connect the other end of the 035-0153-0031 cable to the 002-0039-0031 connector.

3. Connect the 002-0039-0031 connector to the 002-0032-0031 connector.

4. Connect one end of the 035-0152-0032 cable to the 002-0032-0031 connector.

5. Connect the other end of the 035-0152-0032 cable to the TERM IN port on the SRCU.

Connecting a Remote Service Restoration Control Unit

To connect a remote Service Restoration Control Unit (SRCU), you will need the following
materials:

035-0153-0031 cable

002-0039-0031 connector

Two DCE devices with the following characteristics:

— Asynchronous

— Full-duplex

— Flow control ON

— Bit rate of 9600 bps

002-0032-0031 connector