Connecting the Components

4-55

6800-A2-GN22-30

January 1997

To establish the connection, perform the following steps:

1. Connect the grounded end of the 035-0153-0031 cable to an available port on the IPC-1600

card in the host processor.

2. Connect the other end of the 035-0153-0031 cable to the 002-0039-0031 connector.

3. Connect the 002-0039-0031 connector to the 002-0051-0031 connector.

4. Connect one end of the 035-0152-0031 cable to the 002-0051-0031 connector.

5. Connect the other end of the 035-0152-0031 cable to the terminal port on the StarKeeper.

Connecting Remotely

To connect a remote StarKeeper NMS to the host processor, you will need the following materials:

Two 035-0153-0031 cables

Two 002-0039-0031 connectors

Two DCE devices with the following characteristics:

— Asynchronous

— Full-duplex

— Flow control ON

— Bit rates of 1200, 2400, 4800, 9600 bps

Two 002-0050-0031 connectors

Two 035-0152-0031 cables

To establish the connection, perform the following steps at the host processor end:

1. Connect the grounded end of te 035-0153-0031 cable to an available port on the IPC-1600

card in the host processor.

2. Connect the other end of the 035-0153-0031 cable to the 002-0039-031 connector.

3. Connect the 002-0039-0031 connector to the local DCE devices.

Perform the following steps at the remote end:

1. Connect one end of the 035-0152-0031 cable to the terminal port of the StarKeeper.

2. Connect the other end of the 035-0152-0031 cable to the 002-0050-0031 connector.

3. Connect the 002-0050-0031 connector to the remote DCE devices.