Starlan 10 nau diagnostic program – Paradyne 6800 User Manual
Page 316
COMSPHERE 6800 Series Network Management System
8-4
January 1997
6800-A2-GN22-30
StarLAN 10 NAU Diagnostic Program
To test the StarLAN 10 NAU, you need the disk entitled StarLAN 10 Network NAU Diagnostics
that is shipped with the card. To run this diagnostic program, you must power down the Altos
System 5000, remove the StarLAN 10 NAU and reset the jumper settings for IRQ 3 as shown in
Figure 8-3, and replace the board. Once you have this disk, perform the following steps:
Figure 8-3.
StarLAN IRQ Strapping
1. Move the RESET/RUN key on the front panel clockwise to the RUN position to reboot
the System 5000 (if the System 5000 is turned off at this point, move the power switch on
the rear panel to the ON position instead). The System 5000 will run through its normal
power-up sequence and display the following message:
Press spacebar to interrupt autoboot
2. PRESS: the spacebar immediately
The Boot Menu displays (see Figure 8-1).
3. Insert the disk entitled StarLAN 10 Network NAU Diagnostics into the floppy drive and
select Option 2 to boot from the floppy.
4. The diagnostic program will execute automatically. It will check the strap settings (I/O
address, memory address, memory size and memory) to determine if the card is
configured properly.
5. When the diagnostic has completed, press any key to exit the program and remove the
disk from the floppy drive.
Power down the processor and remove the StarLAN 10 NAU. Move the IRQ setting from
3 back to the default 2. (See the section entitled Field Upgrade Packages in Chapter 2,
Preinstallation Steps for the StarLAN 10 NAU, for the correct strap settings.) Replace the
card and power up the processor.