Loading and Restoring Software
5-69
6800-A2-GN22-30
January 1997
NOTE
For the 15000 platform, the division of full-feature workstations
among the three processors should be:
Host Uip-1 Uip-2
7
3
14
Configurations with lower numbers of full-feature workstations
should retain equivalent ratios among the processors for best
performance.
5. If the workstation is connected to a UIP and while still in the XONE directory:
TYPE: copy UIP.CFG XONE.CFG
PRESS: Enter
TYPE: edit XONE.CFG
PRESS: Enter
The DOS editor displays the XONE.CFG file. You should look for the line which starts
with CONN_COMMAND and change WSNAME to the name of the workstation. Look
for the line beginning with CONN_HOST and change NMSUIP to the name of the UIP
machine.
6. If the workstation is connected to an NMS host and while still in the XONE directory:
TYPE: copy HOST.CFG XONE.CFG
PRESS: Enter
TYPE: edit XONE.CFG
PRESS: Enter
The DOS editor displays the XONE.CFG file. You should look for the line which starts
with CONN_COMMAND and change WSNAME to the name of the workstation. Look
for the line beginning with CONN_HOST and change NMSHOST to the name of the host
machine.
7. Reboot the processor to ensure that all changed parameters are properly loaded.