Perform the following steps at the remote end:

1. Connect the grounded end of the 035-0152-0031 cable to one of the user ports on the

System Controller or ACCULINK Network Manager.

2. Connect the other end of the 035-0152-0031 cable to the 002-0050-0031 connector.

3. Connect the 002-0050-0031 connector to the DCE device.

See Appendix A, Modem Settings, for more information on optioning 3810, 3811, 3820, or
2224CEO modems for this application.

Connecting a Local Dial Backup Control Unit

To connect a local 839A DBU, you will need the following materials:

035-0153-0031 cable

002-0039-0031 connector

To establish the connection, perform the following steps:

1. Connect the grounded end of the 035-0153-0031 cable to an available port on the IPC-1600

card in the host processor or the UIP.

2. Connect the other end of the 035-0153-0031 cable to the 002-0039-0031 connector.

3. Connect the 002-0039-0031 connector to the terminal port of the 839A DBU Control Unit.

Connecting a Remote Dial Backup Control Unit

To connect a remote 839A DBU, you will need the following materials:

035-0153-0031 cable

002-0039-0031 connector

Two DCE devices with the following characteristics:

— Asynchronous

— Full-duplex

— Flow control ON

— Bit rates of 1200, 2400, 4800, and 9600 bps

035-0151-0031 cable

To connect a remote DBU, perform the following steps at the processor end:

1. Connect the grounded end of the 035-0153-0031 cable to an available port on the IPC-1600

card in the host processor or the UIP.

2. Connect the other end of the 035-0153-0031 cable to the 002-0039-0031 connector.

3. Connect the 002-0039-0031 connector to the local DCE devices.