background image

Connecting the Components

4-43

6800-A2-GN22-30

January 1997

Netview/PC

Alerts can be exported to the NetView PC. If this option is chosen, your system cannot be
configured with an alert log printer. The diagram in Figure 4-21 illustrates the connection.

You can connect a NetView/PC either locally or remotely. The following sections explain.

Connecting Locally

To connect to a local NetView/PC, you will need the following materials:

035-0153-0031 cable

002-0052-0031 connector

To establish the connection, perform the following steps:

1. Connect the grounded end of the 035-0153-0031 cable to an available port on the IPC-1600

card in the host processor.

2. Connect the other end of the 035-0153-0031 cable to the 002-0052-0031 connector.

3. Connect the 002-0052-0031 connector to the serial port on the NetView/PC.

Figure 4-21. Netview/PC Connection