beautypg.com

Paradyne 6800 User Manual

Page 47

background image

COMSPHERE 6800 Series Network Management System

2-24

January 1997

6800-A2-GN22-30

10. The following messages appear:

Errors have been found during the power on self test in your computer. The
errors were:

Incorrect configuration data in CMOS Memory size in CMOS invalid

SETUP will attempt to correct these errors through auto configuration.
Hit any key to continue.

PRESS: Enter

11. The main SETUP screen appears.

PRESS: Esc

The system reboots.

12. At the prompt,

Boot
.
.

turn off the machine.

Preinstallation Checks for the Integral Ethernet Card

The Integral Ethernet card is installed at the factory but the user should check that the settings on
the card are properly configured.

1. Check the jumper settings on the Ethernet card. Confirm that the 7-pin dip jumper is set

between U7 and U8 to set the card for Thick net transmission (see Figure 2-3).

2. Be sure that the Ethernet card is properly seated in the unnumbered slot above Slot 1 and

the cable is connected to the J5 and J1 pin clusters.