Raid controller in maintenance mode, New settings for dual controllers, Raid c – Promise Technology 2-Year Extended Warranty for VessR2000 RAID Head User Manual
Page 702: Ontroller, Aintenance, Ettings, Ontrollers, New settings for dual
![background image](https://www.manualsdir.com/files/879257/content/doc702.png)
675
Product Manual
rAid c
OntrOller
in
M
AintenAnce
M
Ode
To manage a RAID controller in maintenance mode:
1. Click the Administration tab.
2. Click the Firmware Update icon.
3. Click the Controller Firmware Update option.
4. Compare the Firmware version on Controller 1 and Controller 2.
• If the firmware versions are different, go to “Updating
Firmware on a RAID Subsystem” on page 117.
• If the firmware versions match, contact PROMISE Technical Support
for help installing the correct memory into the RAID controller.
n
ew
s
ettings
fOr
d
uAl
c
OntrOllers
With the second controller successfully installed, make the following settings:
• Redundancy Type – Set to Active-Active or Active-Standby.
See “Making Subsystem Settings” on page 101.
• LUN Affinity – If you choose Active-Active redundancy.
See “Making Controller Settings” on page 113
Note
The Vess subsystem boots its RAID controllers sequentially. With a second
controller installed, your subsystem takes about a minute longer to boot. This
condition is normal.