Viewing ups information (clu), Iewing, Ups i – Promise Technology 2-Year Extended Warranty for VessR2000 RAID Head User Manual
Page 533: Nformation, Clu)
506
Vess R2000 Series Product Manual
Promise Technologies
is 60% to 80%.
Note 4:
To specify UPS units by DNS names, ask your IT administrator to add the DNS names to the DNS
server, before you make UPS settings.
V
iewiNg
ups i
NForMatioN
(Clu)
To view information about a specific
UPS unit:
1. From the Main Menu, highlight
Additional Info and Management
and press
Enter
.
2. Highlight
UPS Management
and press
Enter
.
3. Highlight the UPS unit you want and press
Enter
.
UPS information includes:
•
UPS ID
•
Model Name
•
Serial Number
•
Firmware Version
•
Manufacture Date
•
Voltage Rating
– Output voltage of the UPS.
•
Battery Capacity
– Backup capacity expressed as a percentage.
•
Remaining Backup Time
– Number of minutes the UPS is expected
to power your system in the event of a power failure.
•
Loading Ratio
– Actual output of UPS as a percentage
of the rated output. See the Note below.
•
Temperature
– Reported temperature of the UPS unit.
Note
The maximum recommended Loading Ratio varies among models of UPS
units. The general range is 60% to 80%. If the reported Loading Ratio
exceeds the recommended value for your UPS unit:
Have fewer subsystems or peripherals connected to this UPS unit.
Add more UPS units, or use a higher-capacity UPS unit, to protect your
RAID systems.