beautypg.com

Promise Technology 2-Year Extended Warranty for VessR2000 RAID Head User Manual

Page 688

background image

661

Product Manual

Troubleshooting

Reported

Event

Corrective Action

Rebuild

Rebuild is started

No action is required.

Rebuild is in progress
Rebuild is completed
Rebuild is paused

Resume rebuild when ready.

Rebuild is resumed

No action is required.

Rebuild is stopped

If this action was not intentional, check the

logical drive’s status.

Rebuild stopped internally

Contact Tech Support.

Rebuild is aborted

Reduce system load on the Vess.

Rebuild is queued

No action is required.

Auto rebuild cannot start

Install a target physical drive of adequate

capacity.

Redundancy Check

Redundancy Check is started

No action is required.

Redundancy Check is completed

Redundancy Check is paused

Resume Redundancy Check when ready.

Redundancy Check is resumed

No action is required.

Redundancy Check is stopped

Redundancy Check is aborted due to internal

error

Reduce system load on the Vess.

Redundancy Check encountered inconsistent

block(s)

Check the disk drive check table after RC

and replace disk drive as needed.

Redundancy Check task is queued

No action is required.

Redundancy check is in progress

Redundancy Check task is stopped internally

Restore the disk array to functional status.

Redundancy check is started on

unsynchronized logical drive

No action is required.