beautypg.com

Running transition on a disk array (clu), Locating a disk array (clu), Unning – Promise Technology 2-Year Extended Warranty for VessR2000 RAID Head User Manual

Page 477: Ransition, Rray, Clu), Ocating, Clu) 450

background image

450

Vess R2000 Series Product Manual

Promise Technologies

r

uNNiNg

t

raNsitioN

oN

a

d

isk

a

rray

(Clu)

Transition is the process of replacing a revertible spare drive that is currently part of a disk array with an

unconfigured physical drive or a non-revertible spare drive. For more information, see “Transition” on page 193.

In order to run Transition:

The spare drive must be Revertible.

• You must have an unconfigured physical drive of the same or larger capacity to replace the spare drive.

To run Transition on a disk array:

1. From the Main Menu, highlight

Disk Array Management

and press

Enter

.

2. Highlight the disk array you want and press

Enter

.

3. Highlight

Background Activities

and press

Enter

.

4. Highlight

Transition

and press

Enter

.

Default source and target drives are shown with possible alternative choices.

5. To choose different drive, highlight the drive, press the backspace key to remove the current number,

then type a new number.

6. Highlight

Start

and press

Enter

.

For transition rate, see “Making Background Activity Settings” on page 494.

l

oCatiNg

a

d

isk

a

rray

(Clu)

This feature helps you identify the physical drives assigned to the disk array you are working with in the CLU.

To locate a disk array:

1. From the Main Menu, highlight

Disk Array Management

and press

Enter

.

2. Highlight the disk array you want and press

Enter

.

3. Highlight

Locate Disk Array

and press

Enter

.

The drive carrier status LEDs flash for one minute.