Running transition on a disk array (clu), Locating a disk array (clu), Unning – Promise Technology 2-Year Extended Warranty for VessR2000 RAID Head User Manual
Page 477: Ransition, Rray, Clu), Ocating, Clu) 450
450
Vess R2000 Series Product Manual
Promise Technologies
r
uNNiNg
t
raNsitioN
oN
a
d
isk
a
rray
(Clu)
Transition is the process of replacing a revertible spare drive that is currently part of a disk array with an
unconfigured physical drive or a non-revertible spare drive. For more information, see “Transition” on page 193.
In order to run Transition:
•
The spare drive must be Revertible.
• You must have an unconfigured physical drive of the same or larger capacity to replace the spare drive.
To run Transition on a disk array:
1. From the Main Menu, highlight
Disk Array Management
and press
Enter
.
2. Highlight the disk array you want and press
Enter
.
3. Highlight
Background Activities
and press
Enter
.
4. Highlight
Transition
and press
Enter
.
Default source and target drives are shown with possible alternative choices.
5. To choose different drive, highlight the drive, press the backspace key to remove the current number,
then type a new number.
6. Highlight
Start
and press
Enter
.
For transition rate, see “Making Background Activity Settings” on page 494.
l
oCatiNg
a
d
isk
a
rray
(Clu)
This feature helps you identify the physical drives assigned to the disk array you are working with in the CLU.
To locate a disk array:
1. From the Main Menu, highlight
Disk Array Management
and press
Enter
.
2. Highlight the disk array you want and press
Enter
.
3. Highlight
Locate Disk Array
and press
Enter
.
The drive carrier status LEDs flash for one minute.