Running pdm on a disk array (clu), Unning, Rray – Promise Technology 2-Year Extended Warranty for VessR2000 RAID Head User Manual
Page 476: Clu) 449, Clu)
![background image](https://www.manualsdir.com/files/879257/content/doc476.png)
449
Product Manual
r
uNNiNg
pdM
oN
a
d
isk
a
rray
(Clu)
Predictive Data Migration (PDM) migrates data from the suspect physical drive to a spare drive
before
the
physical drive fails.
Before you can run PDM, you must have a replacement or target physical drive of adequate capacity for your
disk array.
To run PDM on a disk array:
1. From the Main Menu, highlight
Disk Array Management
and press
Enter
.
2. Highlight the disk array you want and press
Enter
.
3. Highlight
Background Activities
and press
Enter
.
4. Highlight
Predictive Data Migration
and press
Enter
.
Default source and target drives are shown with possible alternative choices.
5. To choose different drive, highlight the drive, press the backspace key to remove the current number,
then type a new number.
6. Highlight
Start
and press
Enter
.
See “Enabling Media Patrol, PDM, Power Management - Disk Array (CLU)” on page 447.
For PDM rate, see “Making Background Activity Settings” on page 494.