Promise Technology 2-Year Extended Warranty for VessR2000 RAID Head User Manual
Page 364
337
Product Manual
ctrltempcritical=
(81 - 85) Controller temperature, displayed in Celsius, that the
controller will consider as a critical threshold.
-t
Used with action locate to indicate which type of FRU to locate. If
-t is not specified, it indicates to locate the enclosure.
ctrl
To locate controller.
cooling
To locate cooling unit. It only works with SAS type enclosure.
psu
To locate power supply unit. It only works with SAS type enclosure.
-f
Used with action locate and -t
FRU to locate. The valid values for FRU id are 1,2,3 and 4.
-v
Verbose mode. Used with -a list. VPD information will also be
displayed when using this switch.
Examples
enclosure
enclosure -v
enclosure -a mod -s “tempwarning=40,tempcritical=70”