416

Vess R2000 Series Product Manual

Promise Technologies

M

AnAgIng

the

S

uBSySteM

(clu)

Subsystem Management includes the following functions:

“Making Subsystem Settings (CLU)” on page 416

“Locking or Unlocking the Subsystem (CLU)” on page 417

“Setting Subsystem Date and Time (CLU)” on page 419

“Making NTP Settings (CLU)” on page 419

“Synchronizing with a NTP Server (CLU)” on page 420

M

akiNg

s

ubsysteM

s

ettiNgs

(Clu)

An alias is optional. To set an Alias for this subsystem:

1. From the Main Menu, highlight

Subsystem Management

and press

Enter

.

2. Highlight

Subsystem Settings

and press

Enter

.

3. Make changes as required:

• Type and alias into the Alias field.

Maximum of 48 characters. Use letters, numbers, space between words and underscore.

• Highlight

Redundancy Type

and press the spacebar to

toggle between Active-Active and Active-Standby.
Active-Active – Both RAID controllers are active and can share the load
Active-Standby – One RAID controller is in standby mode and goes active if the other fails

• Highlight

Cache Mirroring

and press the spacebar to

toggle between Enabled and Disabled.