beautypg.com

Accepting an incomplete array (clu), Ccepting, Ncomplete – Promise Technology 2-Year Extended Warranty for VessR2000 RAID Head User Manual

Page 474: Rray, Clu) 447, Nabling, Edia, Atrol, Pdm, p, Ower

background image

447

Product Manual

Manage with CLU

a

CCeptiNg

aN

i

NCoMplete

a

rray

(Clu)

This condition is the result of a missing physical drive. See “Incomplete Array” on page 215 before you use this function.

To accept an incomplete array:

1. From the Main Menu, highlight

Disk Array Management

and press

Enter

.

2. Highlight the disk array you want and press

Enter

.

3. Highlight

Accept Incomplete Array

and press

Enter

.

e

NabliNg

M

edia

p

atrol

, pdM, p

ower

M

aNageMeNt

- d

isk

a

rray

(Clu)

Media Patrol checks the magnetic media on physical drives. Predictive Data Migration (PDM) migrates data from

the suspect physical drive to a spare drive

before

the physical drive fails. Power Management parks the heads,

spins down, and stops rotation after a set period of time to reduce power consumption.

Media Patrol, PDM, and Power Management are enabled by default. Enabled is the recommended setting for

both features.

To enable Media Patrol, PDM, and Power Management on a disk array:

1. From the Main Menu, highlight

Disk Array Management

and press

Enter

.

2. Highlight the disk array you want and press

Enter

.

3. Highlight

Media Patrol

and press the spacebar to toggle between

Enable

and

Disable

.

4. Highlight

PDM

and press the spacebar to toggle between

Enable

and

Disable

.

5. Highlight

Power Management

and press the spacebar to toggle between

Enable

and

Disable

.

6. Press

Control-A

to save your settings.

See “Running PDM on a Disk Array (CLU)” on page 449 and “Making Background Activity Settings” on page

494.

For Power Management settings, see “Making Controller Settings (CLU)” on page 422.