beautypg.com

Raid 1 – mirror, Raid 1 – m, Irror – Promise Technology 2-Year Extended Warranty for VessR2000 RAID Head User Manual

Page 581

background image

554

Vess R2000 Series Product Manual

Promise Technologies

RAID 1 – M

IRRoR

When a logical drive is mirrored, identical data is written to a pair of physical drives, while

reads are performed in parallel. The reads are performed using elevator seek and load balancing

techniques where the workload is distributed in the most efficient manner. Whichever drive is not

busy and is positioned closer to the data is accessed first.

With RAID 1, if one physical drive fails or has errors, the other mirrored physical drive continues

to function. Moreover, if a spare physical drive is present, the spare drive is used as the replacement

drive and data begins to mirrored to it from the remaining good drive.

The logical drive’s data capacity equals the smaller physical drive. For example, a 100 GB

physical drive and a 120 GB physical drive have a combined capacity of 100 GB in a mirrored

logical drive.

If physical drives of different capacities are used, there is unused capacity on the larger drive.

RAID 1 logical drives on Vess consist of two physical drives.

If you want a mirrored logical drive with more than two physical drives, see “RAID 1E – Enhanced

Mirror” on page 556.

RAID 1 Mirrors identical data to two drives

Data Mirror

Physical Drives