beautypg.com

Promise Technology 2-Year Extended Warranty for VessR2000 RAID Head User Manual

Page 498

background image

471

Product Manual

Manage with CLU

loop topology. It is transmitted by an L_Port to initialize or re-initialize the loop.

NOSCount

– Not Operational Primitive Sequence. This primitive sequence is used during link initialization

between two N_Ports in the point-to-point topology or an N_Port and an F_Port in the fabric topology.

NOS is sent to indicate that the transmitting port has detected a link failure or is offline. The expected

response to a port sending NOS is the OLS primitive sequence.

ErrorFrames

– FC devices propagate handshake signals back-and-forth requesting and acknowledging

each byte transferred. FC transfers occur in one frame of data at a time. In this case, the value reflects

the number of frames with errors.

DumpedFrames

– This field specifies the number of frames dumped due to a lack of host buffers.

LinkFailureCount

– Number of times the link has failed. Can be caused by a disconnected link or a bad

fiber element.

LossSyncCount

– Number of times a loss of sync has occurred since last reset.

PrimitiveSeqErrorCount

– An ordered set transmitted repeatedly and used to establish and maintain a link.

LR, LRR, NOS, and OLS are primitive sequences used to establish an active link in a connection between

two N_Ports or an N_Port and an F_Port.

LIP, LPB, and LPE are primitive sequences used in the Arbitrated Loop topology for initializing the loop

and enabling or disabling an L_Port.

InvalidWordSentCount

– Number of invalid words sent since last reset.

InvalidCRCCount

– Invalid Cyclical Redundancy Count. Number of frames received with an invalid CRC

since last reset.

InitiatorIOCount

– I/O Count on the initiator on the host side.