Making ups settings, Aking, Ups s – Promise Technology 2-Year Extended Warranty for VessR2000 RAID Head User Manual
Page 158: Ettings

131
Product Manual
WebPAM PROe - System Configuration
M
akiNg
ups s
ettiNgs
These settings control how the Vess R2600 subsystem detects the UPS unit and responds to data reported by
the UPS unit.
To make UPS settings:
1. Click the
Device
tab.
2. Click the
UPS
icon.
3. Click the
UPS Settings
button.
4. Perform the following actions as required:
• Verify the Current UPS Communication method. See Note 1:
SNMP
– Network connection.
USB
Unknown
– No connection.
• Choose a Detection Setting from the drop-down menu:
Automatic
– Default. If a UPS is detected when the subsystem boots, the settings
changes to Enable.
Enable
– Monitors UPS. Settings changes, reports warnings, and logs events.
Disable
– Does not monitor UPS.
• Type values into the Threshold fields. See Note 2:
Running Time Remaining Threshold
– Actual time below this value resets
adaptive writeback cache to writethrough.
Warning Temperature Threshold
– Actual temperature above this value triggers a
warning and logs an event.
Loading Ratio Threshold
– Actual loading ratio (percentage) above this threshold
triggers a warning and logs an event. See Note 3.
• For UPS units with network cards, type the IP addresses or
DNS names in fields UPS 1 and UPS 2. See Note 4.
5. Press
Submit
to save your settings.
Note 1: Vess R2600 supports multiple UPS units using network or USB connections, but not a combination