Clearing stale and pfa conditions (clu), Learing, Tale – Promise Technology 2-Year Extended Warranty for VessR2000 RAID Head User Manual
Page 463: Pfa c, Onditions, Clu)

436
Vess R2000 Series Product Manual
Promise Technologies
C
leariNg
s
tale
aNd
pFa C
oNditioNs
(Clu)
The Clear Stale and Clear PFA functions only appear when those conditions exist on the physical drive. To clear
a Stale or PFA condition on a physical drive:
1. From the Main Menu, highlight
Physical Drive Management
and press
Enter
.
2. Highlight the physical drive you want and press
Enter
.
3. Highlight
Clear Stale
or
Clear PFA
and press
Enter
.
If a physical drive is still online and shows a PFA error but “Clear PFA” does not appear, use PDM to copy
the data to a new physical drive. See “Running PDM on a Disk Array” on page 136.
If a physical drive is offline and shows a PFA error, rebuild the disk array. See “Rebuilding a Disk Array” on
page 135. After rebuilding, the drive shows Stale. Run
Clear Stale
then run
Clear PFA
.
If the physical drive with a PFA error is a spare, you must delete the drive as a spare, then
Clear PFA
is
available.