Managing with the cli, Making a serial connection, Aking – Promise Technology 2-Year Extended Warranty for VessR2000 RAID Head User Manual
Page 325: Erial, Onnection, Anaging, With

298
Vess R2000 Series Product Manual
Promise Technologies
M
AnAgIng
wIth
the
clI
M
akiNg
a
s
erial
C
oNNeCtioN
Before you begin, be sure the RJ11-to-DB9 serial data cable is connected between the Host
PC and the Vess enclosure, and that both machines are booted and running.
Serial ports on the controllers
Then do the following actions:
1. Change your
terminal emulation program settings to match the following specifications:
• Bits per second: 115200
• Data bits: 8
• Parity: None
• Stop bits: 1
• Flow control: none
2. Start your PC’s terminal VT100 or ANSI emulation program.