beautypg.com

Promise Technology 2-Year Extended Warranty for VessR2000 RAID Head User Manual

Page 680

background image

653

Product Manual

Troubleshooting

Reported

Event

Corrective Action

Initiator

Initiator sent message for detecting an

error

If this message appears repeatedly, contact

Tech Support.

JBOD

JBOD system connected

No action is required.

JBOD system either is removed or

malfunctioned

Check Expander firmware and SAS

connections.

Logical Drive

Logical drive initialization has started

No action is required.

Logical drive Initialization is in progress
Logical drive initialization has completed

Logical drive initialization has paused

Resume the initialization when ready.

Logical drive initialization has resumed

No action is required.

Logical drive initialization has stopped

If this action was not intentional, check the

logical drive’s status.

Logical drive initialization marks the

logical drive offline

Replace the failed physical drive. Delete and

recreate the logical drive.

Logical drive initialization is aborted due

to an internal error.

Reduce system load on the Vess.

Logical drive initialization is queued

No action is required.

Quick logical drive initialization has

started
Quick logical drive initialization has

completed
Quick logical drive initialization has

paused

Resume the initialization when ready.

Quick logical drive initialization has

resumed

No action is required.

Quick logical drive initialization has

stopped

If this action was not intentional, check the

logical drive’s status.

Quick logical drive initialization marks the

logical drive offline

Replace the failed physical drive. Delete and

recreate the logical drive.

Quick logical drive Initialization is aborted

due to an internal error

Reduce system load on the Vess.