Promise Technology 2-Year Extended Warranty for VessR2000 RAID Head User Manual
Page 403
376
Vess R2000 Series Product Manual
Promise Technologies
rc
Usage
rc [-a
rc -a start -l
rc -a stop -l
rc -a pause -l
rc -a resume -l
Summary
The rc command starts, stops, pauses and resumes a Redundancy Check and monitors the
progress of a running Redundancy Check.
Options
-a
Specifies action to perform.
list
(Default) Displays active and paused Redundancy Checks and
their status.
start
Starts a Redundancy Check.
stop
Stops a Redundancy Check.
pause
Pauses a Redundancy Check.
resume
Resumes a paused Redundancy Check.
-l
Specifies the logical drive ID on which to run the Redundancy
Check.
-n
Do not fix inconsistent data. This option causes Redundancy
Check to run without correcting inconsistent data. All inconsistency
errors are reported.
-p
Pause on error. This option causes Redundancy Check to pause
when it encounters inconsistent data. The default is to continue on
error.