beautypg.com

Checking component installation, Clu reports a problem, Hecking – Promise Technology 2-Year Extended Warranty for VessR2000 RAID Head User Manual

Page 639: Omponent, Nstallation, Clu r, Eports, Roblem

background image

612

Vess

R2000

Series

Product

Manual

Promise

Technologies

c

hecking

c

OMPOnent

i

nstAllAtiOn

To check a component’s installation, remove the component, then reinstall the component in its original location.

In most cases, this action fixes a bad connection and allows Vess to detect the component. If this action does not

correct the problem, replace the unit.

On Vess R2000 systems with dual controllers, when one controller’s Status LED is amber and the other controller’s

Status LED is flashing red, it means that the controller with the flashing red LED has entered maintenance mode.

See

“RAID Controller Problems” on page 626.

If the Controller Status LED continues to display amber after startup, contact PROMISE Technical Support. See

“Contacting Technical Support” on page 665.

The Dirty Cache LED flashes during input/output operation. If the LED shines amber and the power is off, there

is unsaved data in the cache. Do NOT power down the Vess while this LED is on.

Clu r

eports

a

p

robleM

The

CLU reports information passively, that is you must determine which functions to check based on the sound

of the Vess R2600’s audible alarm and any amber or red LEDs. SeeVess R2600 is Beeping5 and

LEDs Display

Amber or Red7 for more information.

Check the event logs first. Then check the reported component.

Event Severity Levels
Level

Description

Fatal

Non-recoverable error or failure has occurred.

Critical

Action is needed now and the implications of the condition are serious.

Major

Action is needed now.

Minor

Action is needed but the condition is not a serious at this time.

Warning

User can decide whether or not action is required.

Information

Information only, no action is required.