Viewing a list of disk arrays (clu), Creating a disk array (clu), Creating a disk array – automatic (clu) – Promise Technology 2-Year Extended Warranty for VessR2000 RAID Head User Manual
Page 467: Iewing, Rrays, Clu) 440, Reating, Rray, Utomatic, Clu)
440
Vess R2000 Series Product Manual
Promise Technologies
V
iewiNg
a
l
ist
oF
d
isk
a
rrays
(Clu)
To view a list of disk arrays:
From the Main Menu, highlight
Disk Array Management
and press
Enter
.
The list of disk arrays displays.
C
reatiNg
a
d
isk
a
rray
(Clu)
The CLU provides three methods of creating a disk array:
•
Automatic
– Creates a new disk array following a default set of parameters. Creates a hot spare drive for
all RAID levels except RAID 0, when five or more unconfigured physical drives are available. You can accept
or reject the proposed arrangement but you cannot modify it. See “Creating a Disk Array – Automatic”
•
Express
– You choose the parameters for a new disk array by specifying the characteristics you want.
You can create multiple logical drives at the same time, however they are all identical. Creates a hot spare
drive for all RAID levels except RAID 0. See “Creating a Disk Array – Express”
•
Advanced
– Enables you to specify all parameters for a new disk array, logical drives and spare drives.
See “Creating a Disk Array – Advanced”
C
reatiNg
a
d
isk
a
rray
– a
utoMatiC
(Clu)
To create a disk array using the Automatic feature:
1. From the Main Menu, highlight
Disk Array Management
and press
Enter
.
2. Highlight
Create New Array
and press
Enter
.
3. Highlight
Configuration Method
and press the spacebar to toggle to
Automatic
.
4. Press
Control-A
to save your settings and move to the next screen.
5.
Review the proposed configuration of disk array and logical drives.
• To accept the proposed configuration and create the disk array and
logical drives, highlight
Save Configuration
and press
Enter
.
• To reject the proposed configuration, highlight
Cancel Array Configuration
and press
Enter
. You return to the Disk Arrays Summary screen.