Promise Technology 2-Year Extended Warranty for VessR2000 RAID Head User Manual
Page 461
![background image](https://www.manualsdir.com/files/879257/content/doc461.png)
434
Vess R2000 Series Product Manual
Promise Technologies
• Highlight
CmdQueuing
and press the spacebar to
toggle between
Enabled
and
Disabled
.
• Highlight
MediumErrorThreshold
and press the backspace key to
remove the current value, then type a new smaller value.
See the comments on the next page.
• Highlight
DMA Mode
and press the spacebar to toggle
through UDMA 0 to 6 and MDMA 0 to 2.
For SAS drives:
• Highlight
Write Cache
and press the spacebar to toggle between
Enabled
and
Disabled
.
• Highlight
Read Look Ahead Cache
and press the spacebar
to toggle between
Enabled
and
Disabled
.
• Highlight
CmdQueuing
and press the spacebar to
toggle between
Enabled
and
Disabled
.
• Highlight
MediumErrorThreshold
and press the backspace key to
remove the current value, then type a new smaller value.
See the comments below.
• Highlight
Read Cache
and press the spacebar to toggle between
Enabled
and
Disabled
.
4. Press
Control-A
to save your settings.
See “Viewing Physical Drive Information” below to determine which functions your physical drives
support.
Medium Error Threshold is the number of bad blocks tolerated before the controller marks the drive as
Dead. The default setting is 64 blocks. A setting of zero disables the function. When disabled, no drives
are marked offline even when errors are detected.