beautypg.com

Promise Technology 2-Year Extended Warranty for VessR2000 RAID Head User Manual

Page 461

background image

434

Vess R2000 Series Product Manual

Promise Technologies

• Highlight

CmdQueuing

and press the spacebar to

toggle between

Enabled

and

Disabled

.

• Highlight

MediumErrorThreshold

and press the backspace key to

remove the current value, then type a new smaller value.
See the comments on the next page.

• Highlight

DMA Mode

and press the spacebar to toggle

through UDMA 0 to 6 and MDMA 0 to 2.

For SAS drives:

• Highlight

Write Cache

and press the spacebar to toggle between

Enabled

and

Disabled

.

• Highlight

Read Look Ahead Cache

and press the spacebar

to toggle between

Enabled

and

Disabled

.

• Highlight

CmdQueuing

and press the spacebar to

toggle between

Enabled

and

Disabled

.

• Highlight

MediumErrorThreshold

and press the backspace key to

remove the current value, then type a new smaller value.
See the comments below.

• Highlight

Read Cache

and press the spacebar to toggle between

Enabled

and

Disabled

.

4. Press

Control-A

to save your settings.

See “Viewing Physical Drive Information” below to determine which functions your physical drives

support.

Medium Error Threshold is the number of bad blocks tolerated before the controller marks the drive as

Dead. The default setting is 64 blocks. A setting of zero disables the function. When disabled, no drives

are marked offline even when errors are detected.