Promise Technology 2-Year Extended Warranty for VessR2000 RAID Head User Manual
Page 260
233
Product Manual
WebPAM PROe - System Configuration
Target information includes:
•
ID
– ID number of the target.
•
Name
– iSCSI qualified name (iqn) of this target.
•
Alias
– Maximum of 32 characters. Use letters, numbers, space
between words, and underscore. An alias is optional.*
•
Status
– Up or down.
•
Error Recovery Level
– Error recovery level supported.
• I
nitial R2T
– Allows initiator to begin sending data to a target
without receiving a ready to transfer command.
•
Max Outstanding R2T
– Maximum number of R2T PDUs the
target can have outstanding for a single iSCSI command.
•
Max Burst Length
– Maximum length of a solicited data sequence in bytes.
•
Data Digest
– Adds a data digest (CRC).*
•
Header Digest
– Enables the use of header digest (CRC).*
•
Data Sequence in Order
– Enables placement of data in sequence order
•
Data PTU in Order
– Enables placement of data in PDU order
•
Default Time to Wait
– After a dropped connection, the number
of seconds to wait before attempting to reconnect
•
Default Time to Retain
– Number of seconds after time to wait
(above) before reassigning outstanding commands
•
Uni-directional CHAP Authentication
– Uni-directional (peer)
CHAP authentication, enabled or disabled*
•
Bi-directional CHAP Authentication
– Bi-directional (local)
CHAP authentication, enabled or disabled*
•
Maximum Connections
– The maximum number of concurrent connections
•
Immediate Data
– Enables the initiator to send unsolicited
data with the iSCSI command PDU.
•
First Burst Length
– In bytes.
•
Assigned Portal IDs
•
NOP-In -
Check iSCSI connection status*
Items marked with an asterisk (*) are adjustable under "Making iSCSI Target Settings"