Product Manual

WebPAM PROe - System Configuration

Target information includes:

ID

– ID number of the target.

Name

– iSCSI qualified name (iqn) of this target.

Alias

– Maximum of 32 characters. Use letters, numbers, space

between words, and underscore. An alias is optional.*

Status

– Up or down.

Error Recovery Level

– Error recovery level supported.

• I

nitial R2T

– Allows initiator to begin sending data to a target

without receiving a ready to transfer command.

Max Outstanding R2T

– Maximum number of R2T PDUs the

target can have outstanding for a single iSCSI command.

Max Burst Length

– Maximum length of a solicited data sequence in bytes.

Data Digest

– Adds a data digest (CRC).*

Header Digest

– Enables the use of header digest (CRC).*

Data Sequence in Order

– Enables placement of data in sequence order

Data PTU in Order

– Enables placement of data in PDU order

Default Time to Wait

– After a dropped connection, the number

of seconds to wait before attempting to reconnect

Default Time to Retain

– Number of seconds after time to wait

(above) before reassigning outstanding commands

Uni-directional CHAP Authentication

– Uni-directional (peer)

CHAP authentication, enabled or disabled*

Bi-directional CHAP Authentication

– Bi-directional (local)

CHAP authentication, enabled or disabled*

Maximum Connections

– The maximum number of concurrent connections

Immediate Data

– Enables the initiator to send unsolicited

data with the iSCSI command PDU.

First Burst Length

– In bytes.

Assigned Portal IDs

NOP-In -

Check iSCSI connection status*

Items marked with an asterisk (*) are adjustable under "Making iSCSI Target Settings"