These settings control how the Vess R2000 subsystem detects the UPS unit and responds to data reported by
the UPS unit.
To make UPS settings:
1. From the Main Menu, highlight
Additional Info and Management
and press
Enter
.
2. Highlight
UPS Management
and press
Enter
.
3. Highlight
UPS Settings
and press
Enter
.
4. Perform the following actions as required:
• Verify the Current UPS Communication method. See Note 1:
SNMP – Network connection.
Serial – Serial connection.
Unknown – No connection.
• Choose a Detection Setting from the drop-down menu:
Automatic – Default. If a UPS is detected when the subsystem boots, the settings changes
to Enable.
Enable – Monitors UPS. Settings changes, reports warnings, and logs events.
Disable – Monitors UPS only.
• Type values into the Threshold fields. See Note 2:
Running Time Remaining Threshold – Actual time below this value resets adaptive write-
back cache to writethrough.
Warning Temperature Threshold – Actual temperature above this value triggers a warning
and logs an event.
Loading Ratio Threshold – Actual loading ratio (percentage) above this threshold triggers a
warning and logs an event. See Note 3.
Battery Charge Remaining Threshold – Reserve capacity below this percentage triggers a
warning and logs an event.
• For UPS units with network cards, type the IP addresses or
DNS names in fields UPS 1 and UPS 2. See Note 4.
5. Press
Control-A
to save your settings.
Note 1:
Vess R2000 supports multiple UPS units using network or serial connections, but not a
combination of both methods.
Note 2:
Detection Setting must be set to Auto. If a UPS is detected, the settings changes to Enable.
Note 3:
The maximum recommended Loading Ratio varies among models of UPS units. The general range