Uninterruptible Power Supply (UPS) Management includes the following functions:

“Viewing a List of UPS Units (CLU)” on page 504

“Making UPS Settings (CLU)” on page 505

“Viewing UPS Information (CLU)” on page 506

V

iewiNg

a

l

ist

oF

ups u

Nits

(Clu)

To view a list of UPS units supporting the Vess R2000:

1. From the Main Menu, highlight

Additional Info and Management

and press

Enter

.

2. Highlight

UPS Management

and press

Enter

.

Information in the UPS List includes:

Operational Status

– OK means Normal.

On AC means the UPS is connected to a viable external AC power source.
On Battery means the external AC power source is offline and the UPS is running on bat-

tery power.

Capacity

– Backup capacity expressed as a percentage.

Remaining Minutes

– Number of minutes the UPS is expected

to power your system in the event of a power failure.

Loading

– Actual output of UPS as a percentage of the rated output. See the Note below.

Note

The maximum recommended Loading Ratio varies among models of

UPS units. The general range is 60% to 80%. If the reported Loading

Ratio exceeds the recommended value for your UPS unit:
Have fewer subsystems or peripherals connected to this UPS unit.
Add more UPS units, or use a higher-capacity UPS unit, to protect your

RAID systems.