Uninterruptible Power Supply (UPS) Management includes the following functions:
•
“Viewing a List of UPS Units (CLU)” on page 504
•
“Making UPS Settings (CLU)” on page 505
•
“Viewing UPS Information (CLU)” on page 506
V
iewiNg
a
l
ist
oF
ups u
Nits
(Clu)
To view a list of UPS units supporting the Vess R2000:
1. From the Main Menu, highlight
Additional Info and Management
and press
Enter
.
2. Highlight
UPS Management
and press
Enter
.
Information in the UPS List includes:
•
Operational Status
– OK means Normal.
On AC means the UPS is connected to a viable external AC power source.
On Battery means the external AC power source is offline and the UPS is running on bat-
tery power.
•
Capacity
– Backup capacity expressed as a percentage.
•
Remaining Minutes
– Number of minutes the UPS is expected
to power your system in the event of a power failure.
•
Loading
– Actual output of UPS as a percentage of the rated output. See the Note below.
Note
The maximum recommended Loading Ratio varies among models of
UPS units. The general range is 60% to 80%. If the reported Loading
Ratio exceeds the recommended value for your UPS unit:
Have fewer subsystems or peripherals connected to this UPS unit.
Add more UPS units, or use a higher-capacity UPS unit, to protect your
RAID systems.