Preparing the disk array for transport (clu), Rebuilding a disk array (clu), Running media patrol on a disk array (clu) – Promise Technology 2-Year Extended Warranty for VessR2000 RAID Head User Manual
Page 475: Reparing, Rray, Ransport, Clu), Ebuilding, Unning, Edia
![background image](https://www.manualsdir.com/files/879257/content/doc475.png)
448
Vess R2000 Series Product Manual
Promise Technologies
p
repariNg
the
d
isk
a
rray
For
t
raNsport
(Clu)
To run the Transport function on a disk array:
1. From the Main Menu, highlight
Disk Array Management
and press
Enter
.
2. Highlight the disk array you want and press
Enter
.
3. Highlight
Transport
and press
Enter
.
4.
Press Y to confirm.
r
ebuildiNg
a
d
isk
a
rray
(Clu)
Before you can rebuild, you must have a replacement or target physical drive of adequate capacity for your
disk array.
To rebuild a disk array:
1. From the Main Menu, highlight
Disk Array Management
and press
Enter
.
2. Highlight the disk array you want and press
Enter
.
3. Highlight
Background Activities
and press
Enter
.
4. Highlight
Rebuild
and press
Enter
.
Default source and target drives are shown with possible alternative choices.
5. To choose different drive, highlight the drive, press the backspace key to remove the current number,
then type a new number.
6. Highlight
Start
and press
Enter
.
For rebuild rate, see “Making Background Activity Settings” on page 494.
r
uNNiNg
M
edia
p
atrol
oN
a
d
isk
a
rray
(Clu)
Media Patrol is a routine maintenance procedure that checks the magnetic media on each disk drive. If Media
Patrol encounters a critical error, it triggers PDM if PDM is enabled on the disk array.
See
“Enabling Media Patrol, PDM, Power Management - Disk Array (CLU)” on page 447
For Media Patrol rate, see “Making Background Activity Settings” on page 494.