4 (cli)
To make IPv4 settings manually on the management port:
1. At the command prompt, type
net -a mod -f ipv4 -s
“ followed by:
•
primaryip=
and the IP address
,
•
primaryipmask=
and the subnet mask
,
•
primarydns=
and the DNS server IP address
,
•
gateway=
and the Gateway server IP address
“
and press Enter.
Example:
administrator@cli> net -a mod -f ipv4 -s “primaryip=10.0.0.1,
primaryipmask=255.255.255.0,primarydns=10.0.0.11,gatew
ay=10.0.0.1”
After a moment, the comand prompt reappears, indicating that your setting was successful.
administrator@cli>
2. To verify the settings, at the command prompt, type net -a list -v and press Enter.
The following information displays:
administrator@cli> net -a list -v
-------------------------------------------------------------
---------------
ActiveCtrlId: 1 Port: 1
MaxSupportedSpeed: 100Mbps LinkStatus: Up
ProtocolFamily: IPv4(Enabled)
DHCP: Disabled
IP: 10.0.0.1
IPMask: 255.255.255.0
MAC: 00:01:55:61:18:65
DNS: 10.0.0.11
Gateway: 10.0.0.1
ProtocolFamily: IPv6(Disabled) DHCP: Disabled
IP: ::
IPMask: ::
MAC: 00:01:55:61:18:65
DNS: ::
Gateway: ::