In this example, let us check disk array status.

1. Open the CLU.

2.

Highlight

Disk Array Management

and press Enter.

3. Observe the status of your disk arrays.

DaId Alias OpStatus CfgCapacity

FreeCapacity MaxContiguousCap

-------------------------------------------------------------------------------------------

0

DA0 OK

75.44GB

66.06GB 66.06GB

1

DA1 Degraded 189.06GB

179.68GB 179.68GB

2

DA2 OK

73.57GB

64.20GB 64.20GB

At this point, you can highlight the Degraded array and press

Enter

to see more information. See below.

Disk Array ID: 1

Physical Capacity: 189.06GB

OperationalStatus : Degraded

MaxContiguousCapacity: 11.18GB

FreeCapacity: 179.68 GB

ConfigurableCapacity: 179.68GB

SupportedRAIDLevels: 0 5 10 1E

Disk Array Alias : DA1

MediaPatrol

: Enabled

PDM

: Enabled

Transport

Rebuild

Predictive Data Migration

Transition

Dedicated Spare Drives in the Array

Physical Drives in the Array

Logical Drives in the Array

[Locate Disk Array]

Save Settings [CTRL-A]

Restore Settings [CTRL-R]

Return to Previous Menu

From this screen:

• Highlight

Physical Drives

in the Array and press

Enter

to identify the failed disk drive

• Highlight

Rebuild

and press

Enter

to rebuild the array after you replace the failed disk drive