Checking a reported component, Hecking, Eported – Promise Technology 2-Year Extended Warranty for VessR2000 RAID Head User Manual
Page 641: Omponent
614
Vess
R2000
Series
Product
Manual
Promise
Technologies
C
heCkiNg
a
r
eported
C
oMpoNeNt
In this example, let us check disk array status.
1. Open the CLU.
2.
Highlight
Disk Array Management
and press Enter.
3. Observe the status of your disk arrays.
DaId Alias OpStatus CfgCapacity
FreeCapacity MaxContiguousCap
-------------------------------------------------------------------------------------------
0
DA0 OK
75.44GB
66.06GB 66.06GB
1
DA1 Degraded 189.06GB
179.68GB 179.68GB
2
DA2 OK
73.57GB
64.20GB 64.20GB
At this point, you can highlight the Degraded array and press
Enter
to see more information. See below.
Disk Array ID: 1
Physical Capacity: 189.06GB
OperationalStatus : Degraded
MaxContiguousCapacity: 11.18GB
FreeCapacity: 179.68 GB
ConfigurableCapacity: 179.68GB
SupportedRAIDLevels: 0 5 10 1E
Disk Array Alias : DA1
MediaPatrol
: Enabled
PDM
: Enabled
Transport
Rebuild
Predictive Data Migration
Transition
Dedicated Spare Drives in the Array
Physical Drives in the Array
Logical Drives in the Array
[Locate Disk Array]
Save Settings [CTRL-A]
Restore Settings [CTRL-R]
Return to Previous Menu
From this screen:
• Highlight
Physical Drives
in the Array and press
Enter
to identify the failed disk drive
• Highlight
Rebuild
and press
Enter
to rebuild the array after you replace the failed disk drive