375

Product Manual

Managing with the CLI

-p

Specifies the port number of the TFTP server. If no port number is

given, the default value that will be used is 69.

-e

Specifies the Enclosure ID.

Only used with -a versioninfo option.

If not specified, default value is all enclosures.

-i

Specifies the Controller ID.

Only used with -a versioninfo option.

Enclosure id is required when controller id is specified.

If not specified, default value is all controllers.

-n

Start the flash process/image update in NDIU mode.

This mode is applicable only if the system is in redundant state.

Default mode of flash is DIU (disruptive) mode.

-d

Specifies the physical drive IDs.

Only for physical drive firmware update.

If not specified, all the physical drives, which are supported by the

specified physical drive firmware, are selected.

-l

Display the status of currently running flash process.

-y

Enable non-interactive mode.

Examples

ptiflash -t -s 192.168.1.1 -f fw_multi.ptif -p 69 # for embedded

ptiflash -f fw_multi_20031010.ptif # for in-band

ptiflash -l # list currently running flash process

ptiflash -t -s 192.168.1.1 -f fw_multi.ptif -n # for NDIU mode

ptiflash -t -s 192.168.1.1 -f pd_fw.ptif -d 1,2