beautypg.com

Raid controller problems, Maintenance mode, Raid c – Promise Technology 2-Year Extended Warranty for VessR2000 RAID Head User Manual

Page 653: Ontroller, Roblems, Aintenance

background image

626

Vess

R2000

Series

Product

Manual

Promise

Technologies

RAID c

ontRolleR

P

RoBleMS

RAID controller problems include:

“Maintenance Mode” (below)

“Storage Tab” on page 619

“Taking a RAID Controller out of Maintenance Mode” on page 628

“Unsaved Data in the Controller Cache” on page 630

Controller problems occur when one of the controllers goes into maintenance mode.

M

aiNteNaNCe

M

ode

For Vess with two RAID controllers, one of them enters maintenance mode in the event of:

• A difference of some kind between the two controllers (described below)

• An internal controller failure

When a controller enters maintenance mode, it goes offline and it displays N/A (not accessible) under Readiness

Status.

You must find and correct the cause of the problem and then take the controller out of maintenance mode (see

page 628).