564

Vess R2000 Series Product Manual

Promise Technologies

The data capacity RAID 50 logical drive equals the capacity of the smallest physical drive times the number of

physical drives, minus two.

RAID 50 also provides very high reliability because data is still available even if multiple physical drives fail (one

in each axle). The greater the number of axles, the greater the number of physical drives that can fail without

the RAID 50 logical drive going offline.

Components

Minimum

Maximum

Number of Axles

2

16

Physical Drives per Axle

3

32

Physical Drives per Logical Drive

6

256

RAID 50 Axles

When you create a RAID 50, you must specify the number of axles. An axle re-fers to a single RAID 5 logical

drive that is striped with other RAID 5 logical drives to make RAID 50. An axle can have from 3 to 32 physical

drives, de-pending on the number of physical drives in the logical drive.

The chart below shows RAID 50 logical drives with 6 to 32 physical drives, the available number of axles, and

the resulting distribution of physical drives on each axle.

Recommended Applications for RAID 50:

• File and Application servers

• Transaction processing

• Office application with many users accessing small files