B.6. rule file – Gasboy Fleet Head Office System User Manual
Page 334

332
Figure B-2. Example of Imported Model File
B.6. RULE FILE
The rules, defined in this file, are the means by which the vehicle refueling is limited. The FHO
System offers a comprehensive mechanism of limit definition. By defining the rules, users can set
virtually any desired combination of rules.
The rules defined in this section are individual units, which, in effect, are not applied directly to a
fleet/department/vehicle. Instead, once defining the rules, the fleet manager creates group rules
consisting of a number of rules. These group rules are then imposed on the fleet/department/vehicle
to limit refueling.
The following rule types are available:
f. Cluster: If the gas stations are bundled in clusters. This limit type defines in which clusters
the vehicle may refuel
g. Limits:
Defines fuel limits per day/week/month/year, set in money/volume, for the device
h. Visits:
Specifies the maximum number of visits to fuel stations allowed for the vehicle
per day/week/month
i. Fuel:
Limits the refueling vehicle to certain types of fuel.
Rule file name: Rule_YYYYMMDD_hhmm.CSV
All rules can be imported from one file or separate files for each rule type. Rule file fields vary
depending on the rule type. The following tables describe each rule type fields.
FMS and FHO User’s Manual - MDE-4821