Page 1
INSTALLATION INSTRUCTIONS FOR HIGH HOSE RETRIEVER
FOR MODEL 9800A/2600A WITH VAPOR RECOVERY
This instruction sheet covers the installation of the Model 9800A/2600A Balanced System Vapor Recovery Kit.
If you ordered a vapor recovery kit, 032045, you should have received the following:
Item
Part No.
Description
1
030314
HHR Reel, Premier VR
2
063838
Support Bar, HHR 9800
3
017930
Caplug, 1-1/2 Sq. Tube
4
051956
Screw, 5/16-18x2, SS
5
068079
Washer, 5/16, SS
6
068874
Washer, Std Spring Lock, 5/16, SS
7
056927
Spacer, 1-1/2 x 1-1/4 dia.
8
013250
Bolt, 5/16 Mach Anchor, HHR
9
047219
Plug Button, 7/8
10
051957
Screw, 5/16-18 x 2-1/2, SS
11
064560
Swivel, Hose, 3/4, #36S
12
038502
Nozzle, Emco VR A4005 Stg II
Item
Part No.
Description
13
030301
Hose, Goodyear, Premier Coax, 7’6”
14
066817
Splitter, Emco, 4041-002
15
030407
Hose, 3/4" x 1’6” HW UL
16
017270
Bushing 3/4 x 1”
17
044007
Breakaway Coupling, Coax, Emco,
#A4019-1
18
030303
Hose, Goodyear, Premier Coax 4’6”
19
003336
Boot, Nozzle, VR
20
003719
Hook, Nozzle, VR
21
032024
Installation Instructions (this sheet)
22
035282
Warnings and Safeguards Sheet
1.
Read all the instructions before beginning. A separate instruction sheet is packed with the Emco Wheaton
splitter manifold, which is required for mounting this component. Also read and follow all precautions
regarding remote dispensers and pumps on the Warnings and Safeguards sheet, 035282 (included in this
kit).
2.
Turn off power to the dispenser at the breaker and activate emergency shutoff valve.
3.
Item 14 must be mounted to the unit using the template and instructions furnished by Emco Wheaton.
4.
Item 7 mounts between HHR post and side panel.
5.
Item 8 requires a 5/8” diameter x 1-3/4 deep hole in the island.
6.
Item 16 is required for units with 1” discharge assembly.
7.
Item 17 must be installed approximately 12” downstream of hose retractor clamp.
8.
To reduce the risk of accidental dispensing of fuel, turn off all power.
9.
Use UL-Listed gasoline resisting compound on all joints of gasoline handling fittings. Sealing compound
must also be resistant to gasohol (ethanol and methanol). Do not use Teflon pipe sealing tape. Use
gasoline resistant pipe compound on all male threads only.
10. Tighten all hardware. Plug hole in post with Item 9.
Mounting of Nozzle Boot and Nozzle Hook
1.
Remove the 4 screws from the existing nozzle boot and remove nozzle boot. Add new nozzle boot (item
19) with existing screws.
2.
Remove hardware from existing nozzle hook.
3.
Remove two plugs from lower mounting holes of side panel and plug upper holes.
4.