Gasboy 215A User Manual
Gasboy Hardware
032138 Rev 1212
Page 1
INSTALLATION INSTRUCTIONS FOR
MODEL 215A FRONT LOAD VAPOR RECOVERY KIT 032137
This instruction sheet covers the instruction of the Model 215A Front Load Balanced System Vapor Recovery
Kit. If you are installing another manufacturer’s vapor recovery system, you may need to modify the nozzle boot
using the Modify Nozzle Boot instruction below. Vapor Recovery Kit, 032137 contains the following:
Item
Part No.
Description
1
032671
HHR Kit, Clamp and Reel, VR (GY
Prem)
2
063816
Support Bar, HHR
3
017930
Caplug-1-1/2 Sq. Tube
4
051956
Screw, 5/16-18x2, SS
5
068079
Washer, 5/16, SS
6
068874
Washer, Lock, Std Spring, 5/16, SS
7
056924
Spacer, HHR
8
013250
Bolt, 5/16 Mach Anchor HHR
9
047219
Plug Button, 7/8
10
038605
Nut, 5/16-18 Hex Keps
Item
Part No.
Description
11
064560
Swivel, Hose, 3/4, #36S
12
038502
Nozzle, Emco VR A4005 Stg II
13
030301
Hose, GY Max Prem, 7.5’
14
066817
Splitter, Emco, 4041-02
15
030407
Hose, 3/4” HW UL 1.5
16
017270
Bushing, 3/4 x 1
17
044007
Breakaway Coupling, Coax
OPW66CL0250
18
030303
Hose, GY Max Prem 4.5’
19
032138
Instructions (this sheet)
20
035282
Warnings and Safeguards Sheet
IMPORTANT:
Always use a UL-classified gas and oil resistant pipe compound on all male pipe threads when assembling
these components. All references to pipe compound in these instructions imply UL-classified pipe compound.
1. Read all instructions before beginning. A separate instruction sheet is packed with the EMCO Wheaton
splitter manifold, which is required for mounting this component. Also read and follow all precautions
regarding remote dispensers and pumps on the Warning and Safeguards Sheet, 035282, included in this kit.
2. Turn off power to the dispenser at the breaker and activate emergency shutoff valve.
3. Mount the splitter per the EMCO Wheaton instructions.
Assemble Product Jumper Hose
Assemble 3/4” x 1” bushing (017270) to dispenser outlet. Assemble 3/4” swivel (064560) to one end of the 3/4”
jumper hose (030407). Assemble fixed end of jumper hose to bushing on dispensing outlet, and the swivel end
at the splitter port labeled FUEL.
Mount Hose Retriever
1. Assemble clamp & reel assembly (Item 1) to support post (Item 2) with items 4, 5 & 6.
2. Install reel and post assembly to side of unit with Items 4, 5, 6, 7, & 10, and leave loose. Item 7 mounts
between post and side panel.
3. Making sure the support post is plumb, mark and drill a 5/8” dia. x 1-3/4” deep hole in island. Install anchor
bolt (item 8) into island surface. Install items 4, 5, and 6.
4. Tighten all hardware. Plug hole in post with item 9.
Modify Nozzle Boot
If using a long spout vapor-recovery nozzle, it may be necessary to remove the nozzle restraint bracket and the
lock.