beautypg.com

Excluding hds storage systems from discovery – HP Storage Essentials NAS Manager Software User Manual

Page 93

background image

Storage Essentials 5.00.01 User Guide

63

Excluding HDS Storage Systems from Discovery

When multiple HDS storage systems are managed through a single HiCommand Device Manager,

specific storage systems may be excluded from discovery by using system properties.
To exclude one or more HDS storage systems from discovery, you must modify the
cimom.hds.exclude property. Set the property cimom.hds.exclude to a comma separated

list of serial numbers of the storage systems you want excluded, as shown in the following example:

cimom.hds.exclude=61038,61037

The management server excludes the storage systems with one of the following serial numbers:

61038 and 61037.
If the cimom.hds.exclude property is not specified, the management server discovers and

obtains details from all HDS storage systems managed by the discovered HiCommand Device

Manager.
The IP addresses of excluded elements appear in the discovery (Tools > Storage Essentials >
Home

> Discovery > Setup), topology (Tools > Storage Essentials > Home > Discovery >

Topology

), Discovery Data Collection (Options > Storage Essentials > Discovery > Run

Discovery Data Collection

), or Get Details list (Tools > Storage Essentials > Home >

Discovery

> Details). The management server does not display additional information about

excluded elements in the user interface. The management server, however, does mention in the logs

(Tools > Storage Essentials > Home > Discovery > View Logs) that a provider instance has

been created for an excluded element. You can ignore this message that appears in the logs.
To modify the cimom.hds.exclude property:

1.

Select Options > Storage Essentials > Manage Product Health. Then, click

Advanced in the Disk Space tree.

2.

Click Show Default Properties at the bottom of the page.

3.

Copy the following command. How you copy the text depends on your Web browser. If you are

using Microsoft Explorer or Netscape Navigator, select the text and then right-click the selected

text. Then, select Copy.

#cimom.hds.exclude=61038,61037

4.

Return to the Advanced page.

5.

Paste the copied text into the Custom Properties field. How you paste the text depends on

your Web browser. If you are using Microsoft Explorer or Netscape Navigator, right-click the

field and select Paste.

6.

Make sure the property is not commented out by removing the hash (#) symbol in front of the

property. Add the serial numbers corresponding to the HDS storage systems you want to exclude

form discovery. Separate additional serial numbers with a comma, as shown by the following

example:

cimom.hds.exclude=61038,61037

where 61038 and 61037 are serial numbers for HDS storage systems.

7.

When you are done, click Save.

8.