Issues specific to clariion storage systems, Make the management server a privileged user, For clariion – HP Storage Essentials NAS Manager Software User Manual
Page 371: Emc navisphere cli is required, Issues specific to emc symmetrix storage systems
Storage Essentials 5.00.01 User Guide 341
•
Issues Specific to HP Storage Systems
•
Issues Specific to Engenio Storage Systems
Issues Specific to CLARiiON Storage Systems
The following issues are specific to CLARiiON® storage systems:
•
Make the Management Server a Privileged User for CLARiiON
•
EMC Navisphere CLI Is Required
Make the Management Server a Privileged User
for CLARiiON
Before you can provision a CLARiiON storage system, you must configure it to recognize the
management server as a privileged user. This task can be completed by using NaviCli as follows:
C:\>navicli -h 192.168.1.249 remoteconfig -setconfig -o -adduser
SYSTEM@hostname
•
where
• 192.168.1.249 is the URL of the CLARiiON storage system
• SYSTEM@hostname is the name of the computer running the management server
•
This example tells the CLARiiON storage system at 192.168.1.249 to accept configuration
change requests from management server running on the computer named hostname.
EMC Navisphere CLI Is Required
The EMC Navisphere® CLI is required for the management server to communicate with the
CLARiiON® storage system. At the time this documentation was created, EMC distributed the
Navisphere CLI as part of the EMC Navisphere Software Suite. Contact your EMC representative for
more information about obtaining the Navisphere CLI. Distribution rights for the Navisphere CLI
belong to EMC. EMC Navisphere CLI Is Required
In Navisphere Manager add one of the following to the privilege user section:
SYSTEM@name_of_my_management_server
SYSTEM@IP_of_my_management_server
where
•
name_of_my_management_server is the DNS name of the computer running the
management server software
•
IP_of_my_management_server is the IP address of the computer running the management
server software
When you discover the CLARiiON storage system, provide the IP address for the CLARiiON storage
system and the user name and password used to log into Navisphere.
Issues Specific to EMC Symmetrix Storage Systems
The following issues are specific to EMC Symmetrix Storage Systems:
•
About Provisioning on EMC Symmetrix Storage Systems
•
LUN Provisioning Is Not Supported with Solutions Enabler 4.3
- Storage Essentials Provisioning Manager Software Storage Essentials Backup Manager Software Storage Essentials Chargeback Manager Software Storage Essentials Report Designer Software Storage Essentials Global Reporter Software Storage Essentials Enterprise Edition Software Storage Essentials Exchange Viewer Software Storage Essentials File System Viewer Software