Discovery from hp sim discovery from hp se – HP Storage Essentials NAS Manager Software User Manual
Page 69
Storage Essentials 5.00.01 User Guide
39
•
To manage a fabric of Sun StorEdge and/or QLogic switches, every switch in the fabric must be
included in the discovery list. If a switch is not included in the discovery list, it may show up as a
generic host system.
•
No ports are reported for uninstalled blades or GBICs.
•
The default SNMP trap listener port for all Sun StorEdge switches is 162. To change this port,
see ”
Changing the SNMP Trap Listener Port for Sun StorEdge Switches
•
To receive events from Sun StorEdge switches, verify the SNMP trap community string is set to
public in SANbox Manager or via telnet. Also, make sure the SNMP traps are configured to be
sent to the management server. See ”
” on page 409 for more information.
Keep in mind the following for QLogic SMI-S switches:
•
A user name and password are required to discover any SMI-S switch.
•
You must perform Get Details or Discovery Data Collection to obtain all available information
from QLogic SMI-S switches—otherwise, attributes such as vendor, fabric, and port information
will be missing for the QLogic SMI-S switches.
Discovery from HP SIM
IMPORTANT:
Provide the SNMP credentials in the WBEM settings section on the System Protocol
Settings page (Options > Protocol Settings > System Protocol Settings). Only the WBEM
default credentials are passed from HP SIM to HP SE. Any default credential information you set up
in regards to SNMP is not passed from HP SIM to HP SE.
To discover a Sun StorEdge or QLogic switch in HP Insight Manager, provide the following:
•
System name or primary IP address of the a Sun StorEdge or QLogic switch you want to
discover. See ”
Adding an IP Range for Scanning
” on page 24 for more information.
•
Do one of the following:
• For Sun StorEdge or QLogic switches with SNMP connections:
Provide the user name for the switch. This is the public community SNMP string for the switch.
• For QLogic switches with SMI-S connections:
Provide the SMI-S user name.
•
HP SIM does not allow blank passwords. Do one of the following:
• Enter anything for the password for Sun StorEdge and QLogic SNMP switches.
• A password is required on SMI-S switches. Enter the password.
See the HP SIM documentation for more details.
Discovery from HP SE
To discover Sun StorEdge or QLogic switches:
1.
Click Tools > Storage Essentials > Home > Discovery > Setup. See ”
Discovery Pages for HP SIM and HP SE
” on page 17 if needed.
2.
Select Step 1 at the top of the page.
- Storage Essentials Provisioning Manager Software Storage Essentials Backup Manager Software Storage Essentials Chargeback Manager Software Storage Essentials Report Designer Software Storage Essentials Global Reporter Software Storage Essentials Enterprise Edition Software Storage Essentials Exchange Viewer Software Storage Essentials File System Viewer Software